Report Number: 021245-F
December 3, 2002
Page
10
Rev.
00
MEASUREMENT PROCEDURE
(FINAL LINE CONDUCTED EMISSION TEST)
1) EUT and support equipment was set up on the test bench as per step 10 of the preliminary test.
2) A scan was taken on both power lines, Line 1 and Line 2, recording at least the six highest emissions.
Emission frequency and amplitude were recorded into a computer in which correction factors were used
to calculate the emission level and compare reading to the applicable limit. If EUT emission level was
less 2dB to the A.V. limit in Q.P. mode, then the emission signal was re-checked using an Average
detector.
3) The test data of the worst case condition(s) was reported on the Summary Data page.
Data Sample:
Freq.
MHz
Q.P.
Raw
dBuV
Average
Raw
dBuV
Q.P.
Limit
dBuV
Average
Limit
dBuV
Q.P.
Margin
dB
Average
Margin
dB
Note
x.xx 43.95 --- 56 46 -12.05 --- L 1
Freq. = Emission frequency in MHz
Raw dBuV = Uncorrected Analyzer/Receiver reading
Limit dBuV = Limit stated in standard
Margin dB = Reading in reference to limit
Note = Current carrying line of reading
--- = The emission level complied with the Average limits,
with at least 2 dB margin, so no further recheck.
Calculation example:
Margin (dB) = RAW (dBuV) Limit (dBuV)
LINE CONDUCTED EMISSION LIMIT
Maximum RF Line Voltage
Frequency
Q.P. AVERAGE
150kHz-500kHz 79dBuV 66dBuV
500kHz-5MHz 73dBuV 60dBuV
5MHz-30MHz 73dBuV 60dBuV
Note: The lower limit shall apply at the transition frequency.