UNO-3072LA User Manual 50
Appendix B Programming the Watchdog
Timer
To program the watchdog timer,
you must write
a program which writes I/
O
port
address
443 (hex). The
output data is a
value of
time interval. The
value range is from
01 (hex) to 3E (hex),
and
the related time interval is 1
sec. to 62
sec.
Data
Time Interval
01
1 sec.
02
2 sec.
03
3 sec.
04
4 sec.
..
..
..
3E
62 sec.