4.7.2 AlarmEnable
Enables the alarm in either momentary or latching mode. This function only supports ADAM
modules.
Input:
Data type Parameter Description
DevHandle The handler id of the device specified by DevNum as
assigned by the LabVIEW program.
Channel The channel for alarm monitoring
LatchMode Momentary(0), Latching(1)
Enable Enable(1), Disable(0)
error in A cluster containing error information, such as the
status, code, and source elements that is passed from
a previous linked VI.
Output:
Data type Parameter Description
DevHandle The handler id of the device specified by DevNum as
assigned by the LabVIEW program.
error out A cluster containing error information. If error in
indicated an error, the status, code, and source
elements of error out have the same values as the
corresponding elements of error in