Advantech PCI-1718 Series Instrukcja Użytkownika Strona 53

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 94
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 52
45 Chapter 4
4.3.3 Pacer Trigger Mode with Interrupt and FIFO
MUX Scan
Channel Control &
A/D Range
Control
Set Scan Channel
w Base+0 1H
w Base+0 2 H
Clear FIFO
Set To Pacer
Trigger Mode To
Enable Trigger
w Base+0 9H
w Base+ 19H
Interrupt
Set Pacer Trigger
and Disable
Generated
Interrupt
Set To Software
Trigger Mode To
Disable Trigger
w Base+ 0AH
w Base+ 09H
Enable FIFO
Interrupt
w Base+0 6H
Set ISR
Clear FIFO
Interrupt Request
w Base+ 14 H
Clear FIFO
Interrupt Request
Get 512
Samples data
(Half-Full of FIFO)
w Base+ 14 H
r Base+ 17H
r Base+18H
Start ISR
Clear System
Interrupt request
End of ISR
Set Pacer Rate
Base+0 CH~
Base+0FH
Clear System
Interrupt Request
w Base+0 2H
Enable System To
Accept Interrupt
System Ready For
Data Acquisition
Set To Software
Trigger Mode To
Disable Trigger
Restore ISR
Disable Generated
Interrupt
w Base+0 9 H
w Base+0 9H
Disable System
To Accept
Interrupt
Clear FIFO w Base+ 19H
Stop ISR
Przeglądanie stron 52
1 2 ... 48 49 50 51 52 53 54 55 56 57 58 ... 93 94

Komentarze do niniejszej Instrukcji

Brak uwag