Chapter 2 Getting Started 9
2.1.2 Serial Architecture
The ADAM-4579 provides two modes to meet your needs. One is
command mode; the other is data mode. You can use it according to
your application.
2.1.2.1 Data Mode
The Data mode provides a certain amount of transparence and
flexibility in transmitting data between two devices. If you wan to
transmit data to any networking device from serial device directly, you
can select data mode.
In data mode, the data from the serial port of one ADAM-4579 can be
automatically sent to the other networking device, without the need for
an intermediate PC. Thus, serial devices will be no longer bundled with
operation system and behave like network devices to send /receive
data via Ethernet.
2.1.2.2 Controlling Mode
In controlling mode, the ADAM-4579 presents a modem interface to
the attached serial device: it accepts AT-style modem commands to
connect / disconnect to other networking device. If you want serial
device running application program to connect/disconnect to different
devices dynamically, you can use controlling mode.
The controlling mode provides three modem AT-style commands. The
serial devices can use these commands to control ADAM-4579 to
connect/disconnect to remote networking device. Thus, intelligent
serial devices such as stand-alone PLC will send /receive data to/from
devices one by one via Ethernet.