34 ADAM-4579 User’s Manual
After you have connected to another serial device via ADAM-4579, you may
need to disconnect. Then you can use the command "+++"to disconnect. To
do this leaves your keyboard idle (don't press any keys) for at least several
seconds, then press "+" three times. You can set "Guard time" to define the
idle time. Be sure that you have to press "+" over the idle time.
For example: <Guard time> + <Guard time> + <Guard time> +
The following commands are available for ADAM-4579.
Comma nd Func tion
ATDT< IP address>
<TCP port><CR>
“Forms a TCP connection to the specified host.
Ex: ATD T 192.0.55.22:5200
In above example, the ADAM-4579 forms a raw TCP connection
to the networking device (192.0.55.22). The TCP port is 5200.”
ATA <CR> Answering an incoming call
+++<CR>
Returns the user to the command prompt when entered from the
serial port during a remote host connection.
The following table illustrates the response.
<LF><CR> OK <LF><CR> Commands are executed correctly
<LF><CR> CONNECT <LF><CR> Connect to other device
<LF><CR> RING ddd.ddd.ddd
<LF><CR>
Detect the connection requesdt from o the r
device, which IP address is
ddd.ddd.ddd.ddd.
<LF><CR> DISCONNECT <LF><CR> Disconnect from other device
<LF><CR> ERROR <LF><CR> Incorrect commands
<LF><CR> FAIL <LF><CR>
If you issu an ATDT command and can not
connect to the device, it will response
“FAIL”.
Komentarze do niniejszej Instrukcji