Dialogic
®
System Release 6.1 CompactPCI for Windows
®
Release Update 129
Resolved IPY00080020 -- 190 SNMP OID data type returned by the DLGHWINF,
DLGSRPRF, DLGR4DEV, and DLGDS1 agents
does not always match the type definitions in their
respective MIB files.
Resolved IPY00079590 -- 189 SNMP An incorrect Enterprise ID is returned
Resolved IPY00045292 -- 178 SNMP When using SNMP and querying the
dlgIsdnSigProtocol OID in the DLGCISDN MIB, it
returns ''4ess''; the proper string returned should be
''4ess/Ni2” instead.
Resolved IPY00036855 -- 139 SNMP When using MIB2 from RFC1213, Dialogic
®
SNMP
agent fails to return valid information when a “get”
command is issued.
Resolved IPY00091022 -- 198 SS7 SS7 software fails to start due to a tracing function
defect.
Resolved IPY00045239 -- 176 SS7 The small window of time between the receipt of a
GCEV_UNBLOCKED and gc_WaitCall( )
completion was enough to miss GC/SS7 calls; the
library discarded calls received during that window.
Resolved IPY00045224 -- 176 SS7 Dialogic
®
Global Call SS7 application did not work
properly the first time after the Dialogic
®
SS7
Boards were initialized; the application needed to be
torn down and brought up again for it to work
properly.
Resolved IPY00044425 -- 175 SS7 A GCEV_OFFERED event was sent before the
application issued gc_WaitCall( ); this is not the
correct call flow order in Global Call.
Resolved IPY00044100 -- 175 SS7 The GC SS7 server log level configuration in
gcss7.cfg is not working; whether the debug level is
set to “All,” “None,” or “Errors,” the log file is the
same as “All.”
Resolved IPY00037918 -- 139 SS7 The RSI link goes down intermittently.
Resolved IPY00037767 -- 135 SS7 The GCSS7 library does not generate the
GCEV_MOREINFO event if it receives a SAM
message with only STOP digit (0xf) after the
application has already issued gc_CallAck( ).
Resolved IPY00037632 -- 135 SS7 If there is a delay in the SS7 server picking up
messages from the IPC queue, an
ERROR_IO_PENDING occurs and the SS7 library
terminates the IPC. This causes all the circuits to
get blocked, as there is no more connection with the
SS7 service. This is causing the IVRs to get a
sudden circuit block from the switch in all of its SS7
circuits.
Resolved IPY00043230 -- 166 Standard Runtime
Library (SRL)
An access violation occurs during sr_waitevtEx( )
processing.
Issues Sorted By Type, Dialogic
®
System Release 6.1 CompactPCI for Windows
®
(Continued)
Issue Type Defect No.
PTR
No.
SU
No.
Dialogic
®
Product(s) or
Component(s)
Description